Esophagogastric Junction Distensibility on Functional Lumen Imaging Probe Topography Predicts Treatment Response in
Anand S Jain1, Dustin A Carlson2, Joseph Triggs2
1Division of Gastroenterology and Hepatology, Emory University School of Medicine, Atlanta, Georgia, USA.
Introduction:
To compare the utility of the distensibility index (DI) on functional lumen imaging probe (FLIP) topography to other esophagogastric junction (EGJ) metrics in assessing treatment response in achalasia in the context of esophageal anatomy.
Methods:
We prospectively evaluated 79 patients (at ages 17-81 years; 47% female patients) with achalasia during follow-up after pneumatic dilation, Heller myotomy, or per-oral endoscopic myotomy with timed barium esophagram, high-resolution impedance manometry, and FLIP. Anatomic deformities were identified based on consensus expert opinion. Patients were classified based on anatomy and EGJ opening to determine the association with radiographic outcome and Eckardt score (ES).
Results:
Twenty-seven patients (34.1%) had an anatomic deformity-10 pseudodiverticula at myotomy, 7 epiphrenic diverticula, 5 sigmoid, and 5 sinktrap. A 5-minute column area of >5 cm was best associated with an ES of >3, with a sensitivity of 84% (P = 0.0013). Area under the curve for EGJ metrics in association with retention was as follows: DI, 0.90; maximal EGJ diameter, 0.76; integrated relaxation pressure, 0.64; and basal esophagogastric junction pressure, 0.53. Only FLIP metrics were associated with retention given normal anatomy (DI 2.4 vs 5.2 mm/mm Hg and maximal EGJ diameter 13.1 vs 16.6 mm in patients with and without retention, respectively; P values < 0.0001 and 0.002). Using a DI cutoff of <2.8 as abnormal, 40 of 45 patients with retention (P = 0.0001) and 23 of 25 patients with an ES of >3 (P = 0.02) had a low DI and/or anatomic deformity. With normal anatomy, 21 of 22 patients with retention had a low or borderline low DI.
Discussion:
The FLIP DI is most useful metric for assessing the effect of achalasia treatment on EGJ opening. However, abnormal anatomy is an important mediator of outcome and treatment success will be modulated by anatomic defects that impede bolus emptying.
Related Concept Videos
Tension Response at Adherens Junctions
α-Catenin as a Mechanosensory Protein
The α-catenin of adherens junctions is an allosteric protein with three VH (vinculin...
Methods of Obtaining Topography
Classifying Matter by State
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Physical and Chemical Properties of Matter
The Atomic Theory of Matter


