High-throughput metabolomics screen coupled with multivariate statistical analysis identifies therapeutic targets in

Heng Fang1, Ai-Hua Zhang1, Hui Sun1

  • 1National Chinmedomics Research Center, Sino-America Chinmedomics Technology Collaboration Center, National TCM Key Laboratory of Serum Pharmacochemistry, Laboratory of Metabolomics, Department of Pharmaceutical Analysis, Heilongjiang University of Chinese Medicine, Heping Road 24, Harbin, China.

Related Concept Videos

Mass Spectrometry: Alcohol Fragmentation01:03

Mass Spectrometry: Alcohol Fragmentation

Alcohols (R-OH) ionize to lose one non-bonded electron from the oxygen atom, forming molecular ions. Due to their tendency to fragment rapidly, the intensity of the molecular ion peak in the mass spectrum is weak or sometimes absent. The fragmentation patterns for alcohols occur in two ways, i.e. ⍺-cleavage and dehydration. During ⍺-cleavage, the bond at the ⍺-position adjacent to the hydroxyl group cleaves to give a resonance-stabilized cation and a radical. However, intramolecular...
4.5K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.7K
Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
3.8K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
1.8K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.4K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.0K