Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI
Seungbin Ko1, Byungkuen Yang1, Jee-Hyun Cho2
1Department of Mechanical Engineering, Hanyang University, Seoul, 04763, South Korea.
Abstract:
Four-dimensional flow magnetic resonance imaging (4D flow MRI) is a versatile tool to obtain hemodynamic information and anatomic information simultaneously. The wall shear stress (WSS), a force exerted on a vessel wall in parallel, is one of the hemodynamic parameters available with 4D flow MRI and is thought to play an important role in clinical applications such as assessing the development of atherosclerosis. Nevertheless, the accuracy of WSS obtained with 4D flow MRI is rarely evaluated or reported in literature, especially in the in vivo studies. We propose a novel and facile criterion called Reynolds resolution to assess the accuracy of WSS estimation in 4D flow MRI studies. Reynolds resolution consists of a spatial resolution, encoding velocity, kinematic viscosity of a working fluid, and signal-to-noise ratio, which are readily accessible information in 4D flow MRI measurements. We explored the relationship between Reynolds resolution and the WSS error. To include diverse and extensive cases, we measured three circular tubing flows with a diameter of 40, 8, and 2 mm. The 40 mm tubing flow was measured by 3 Tesla (T) human MR scanner with a knee coil and spatial resolution of 0.5 mm. The 8 and 2 mm tubing flows were both measured by 4.7 T MR scanner, but the scans were performed with a conventional birdcage coil (8 mm tubing) and a custom-made solenoid coil (2 mm tubing), respectively. The spatial resolution was varied from 0.2, 0.4 or 0.8 mm for the 8 mm tubing flow, but was fixed at 0.090 mm for 2 mm tubing flow. In addition, the near-wall velocity gradient, required to be determined prior to the WSS, was calculated using two methods; these included assuming a linear velocity profile or quadratic velocity profile near wall. The accuracy of WSS obtained using each method and tubing flow was evaluated against the theoretical WSS value. As a result, we found that Reynolds resolution is in logarithmic relation to the WSS error.
More Related Videos
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
07:07Author Spotlight: High-Resolution 4D Light-Sheet Imaging and Virtual Reality in Zebrafish for Single-Cell Analysis of Heart Function
Published on: January 5, 2024
Related Concept Videos
Improving Translational Accuracy
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Uncertainty in Measurement: Accuracy and Precision
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Potential-Energy Criterion for Equilibrium