Related Experiment Video
Updated: Jan 29, 2026

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Identifying the ideal tracheostomy site based on patient characteristics during percutaneous dilatational
Jiho Park1, Woosuk Chung1,2, Seunghyun Song1
1Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Background:
We previously reported that percutaneous dilatational tracheostomy (PDT) can be safely performed 2 cm below the cricothyroid membrane without the aid of a bronchoscope. Although our simplified method is convenient and does not require sophisticated equipment, the precise location for tracheostomy cannot be confirmed. Because it is recommended that tracheostomy be performed at the second tracheal ring, we assessed whether patient characteristics could predict the distance between the cricothyroid membrane and the second tracheal ring.
Methods:
Data from 490 patients who underwent three-dimensional neck computed tomography from January 2012 to December 2015 were analyzed, and the linear distance from the upper part of the cricoid cartilage (CC) to the lower part of the second tracheal ring (2TR) was measured in the sagittal plane.
Results:
The mean CC-to-2TR distance was 25.26 mm (95% CI 25.02-25.48 mm). Linear regression analysis showed that the predicted CC-to-2TR distance could be calculated as -5.73 + 0.2 × height (cm) + 1.22 × sex (male: 1, female: 0) + 0.01 × age (yr) -0.03 × weight (kg) (adj. R2 = 0.55).
Conclusions:
These results suggest that height and sex should be considered when performing PDT without bronchoscope guidance.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning II: Procedure
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...