A newly synthesized graft copolymer for magnetic solid phase microextraction of total selenium and its electrothermal atomic absorption spectrometric determination in food and water samples
Related Experiment Video
Updated: Jan 29, 2026

Solid-state Graft Copolymer Electrolytes for Lithium Battery Applications
Published on: August 12, 2013
Ayse Nihan Acikkapi1, Mustafa Tuzen1, Baki Hazer2
1Tokat Gaziosmanpasa University, Chemistry Department, 60250 Tokat, Turkey.
Abstract:
A newly synthesized polystyrene-g-polyoleic acid-g-polyethylene glycol graft copolymer (PoleS-PEG) was used as adsorbent in the solid phase microextraction of selenium ions by using electrothermal atomic absorption spectrometry (ETAAS). Neodymium magnet was used for separation of analyte ions. Various analytical parameters such as pH, adsorbent amount, mixing time, eluent solution, sample volume, etc. were optimized. The matrix effects of some cations and anions were also studied. The capacity of the adsorbent was found 11.5 mg g-1. The preconcentration factor was found to be 50. The detection limit (LOD) and quantification limit (LOQ) were found 6.06 ng L-1 and 20 ng L-1, respectively. The calibration curve was linear in the range of 0.02-4.0 μg L-1. Relative standard deviation was found 3.2%. The accuracy of the method was provided by using standard reference materials. The optimized method was successfully applied to natural water and food samples.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Mineral, Vitamin and Water Absorption
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...