Related Experiment Video
Updated: Jan 29, 2026

Applying Dynamic Strain on Thin Oxide Films Immobilized on a Pseudoelastic Nickel-Titanium Alloy
Published on: July 28, 2020
Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a
Tripti Tikku1, Rohit Khanna1, Akhil Agarwal1
1Department of Orthodontics, Babu Banarasi Das College of Dental Sciences, Lucknow, Uttar Pradesh, India.
Background:
To determine and compare the force-deflection values of different types of nickel-titanium (NiTi) wires during unloading phase at varying deflections, that is 1 mm, 1.5 mm, 2 mm, and 2.5 mm, with the use of self-ligating ceramic brackets using modified bending test on a typodont under controlled temperature conditions.
Materials And Methods:
In this in vitro study total of 45 wires of ovoid shape of three different NiTi wires - pseudoelastic NiTi (Group I), heat activated NiTi (Group II), and esthetic coated NiTi (Group III) for maxillary arch were tested after insertion in ceramic self-ligating brackets bonded to plastic teeth of phantom jaw. The maxillary left lateral incisor was removed to simulate a malpositioned tooth which acted as the load site, and load-deflection characteristics were measured during unloading using Instron, and data analyzed statically by two-way analysis of variance, Tukey's post hoc test, intraclass correlation coefficient and Pearson correlation coefficient. A two-sided (α = 2) P < 0.05 was considered statistically significant.
Results:
When wires were compared at each deflection statistically significant difference was observed between the three groups of wires (Group I > Group II > Group III) at all the four levels of deflection except for Group II versus Group III at 1 mm, 1.5 mm, and 2 mm of deflection. Statistically significant difference was noted in mean load values for comparisons made at different deflections for each wire except for the comparison made at 1.5 versus 2 mm for Group II and Group III.
Conclusion:
Overall comparison showed esthetic coated Ni-Ti wires gave significantly lower mean load values, followed by heat activated and pseudoelastic NiTi wires. Thus, heat activated NiTi wires are best suited in patients with severe malpositions/periodontitis, while for esthetically conscious patients esthetic coated NiTi can be used.
Related Concept Videos
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Characteristics of Life
Bending
In pure bending, the bending stress in a beam is calculated based on the bending moment and...
Symmetric Member in Bending
Unsymmetric Bending