Related Experiment Video
Updated: Jan 29, 2026

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
Published on: February 1, 2022
Comparison of methods for converting Dylos particle number concentrations to PM2.5 mass concentrations
Remy Franken1, Thomas Maggos2, Asimina Stamatelopoulou2
1Netherlands Organisation for Applied Scientific Research TNO, Zeist, The Netherlands.
Abstract:
The aim of this study was to (a) develop a method for converting particle number concentrations (PNC) obtained by Dylos to PM2.5 mass concentrations, (b) compare this conversion with similar methods available in the literature, and (c) compare Dylos PM2.5 obtained using all available conversion methods with gravimetric samples. Data were collected in multiple residences in three European countries using the Dylos and an Aerodynamic Particle Sizer (APS, TSI) in the Netherlands or an optical particle counter (OPC, GRIMM) in Greece. Two statistical fitted curves were developed based on Dylos PNC and either an APS or an OPC particle mass concentrations (PMC). In addition, at the homes of 16 volunteers (UK and Netherlands), Dylos measurements were collected along with gravimetric samples. The Dylos PNC were transformed to PMC using all the fitted curves obtained during this study (and three found in the literature) and were compared with gravimetric samples. The method developed in the present study using an OPC showed the highest correlation (Pearson (R) = 0.63, Concordance (ρc ) = 0.61) with gravimetric data. The other methods resulted in an underestimation of PMC compared to gravimetric measurements (R = 0.65-0.55, ρc = 0.51-0.24). In conclusion, estimation of PM2.5 concentrations using the Dylos is acceptable for indicative purposes.
More Related Videos
05:07Development of a Nose-only Inhalation Toxicity Test Chamber That Provides Four Exposure Concentrations of Nano-sized Particles
Published on: March 18, 2019
13:17Manufacture of Concentrated, Lipid-based Oxygen Microbubble Emulsions by High Shear Homogenization and Serial Concentration
Published on: May 26, 2014
Related Concept Videos
Solution Concentration and Dilution
Concentration Cells
Consider the following voltaic cell:
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Calculating Equilibrium Concentrations
A more...
Stress Concentrations
The stress...
Stress Concentrations