Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Advancements and Challenges in Surgical Treatments for Postamputation Pain
Published on: March 8, 2024
Effects of two frequencies of vibration on the maxillary canine distalization rate and RANKL and OPG secretion: A
Natchanon Siriphan1, Chidchanok Leethanakul1, Udom Thongudomporn1
1Faculty of Dentistry, Orthodontic Section, Department of Preventive Dentistry, Prince of Songkla University, Hat Yai, Thailand.
Objectives:
To investigate the effects of 30 and 60 Hz vibratory stimulus on canine distalization and RANKL and OPG secretion.
Setting And Sample Population:
Sixty patients requiring canine distalization at the Orthodontic Clinic, Prince of Songkla University.
Materials And Methods:
Patients were randomly assigned to 30 Hz vibration (n = 20), 60 Hz vibration (n = 20), or the control group (n = 20). Modified electric toothbrushes were used to apply vibration to the randomly selected canine for 20 min/day by the investigator combined with 60 cN continuous distalization force from day 1 to day 7. RANKL and OPG were analysed before (T1) and 24 hours (T2), 48 hours (T3) and 7 days (T4) after initiation of distalization. From day 8, vibratory devices were used by the subjects at home. Rate of canine distalization (T1 to 3 months after initiation [T5]) was calculated. Kruskal-Wallis tests were used for multiple comparisons (significance level, 0.05).
Results:
Canine distalization rate was not different between groups (median; 0.82, 0.87, and 0.83 mm/month for 30, 60 Hz, and control group, respectively; P > 0.05). No within- or between-group differences in RANKL and OPG were observed (P > 0.05), except RANKL on the compression side of the control group was significantly higher at T2, T3 and T4 than T1 (P < 0.001).
Conclusion:
In the clinic, 30 and 60 Hz vibratory stimulus have no additive effect on rate of canine distalization rate, RANKL and OPG secretion or RANKL/OPG ratio.
Related Concept Videos
Load-frequency control
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Vibrating Concrete

