Related Experiment Video
Updated: Jan 29, 2026

Standardized Measurement of Nasal Membrane Transepithelial Potential Difference NPD
Published on: September 13, 2018
Patient versus proxy response on global health scales: no meaningful DIFference
Brittany R Lapin1,2, Nicolas R Thompson3,4, Andrew Schuster4
1Quantitative Health Sciences, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, JJ3-603, Cleveland, OH, 44195, USA. LapinB@ccf.org.
Purpose:
Assessment of outcomes from a proxy is often substituted for the patient's self-report when the patient is unable or unwilling to report their status. Research has indicated that proxies over-report symptoms on the patient's behalf. This study aimed to quantify the extent of proxy-introduced bias on the Patient-Reported Outcomes Measurement Information System Global Health (PROMIS GH) scale for mental (GMH) and physical (GPH) scores.
Methods:
This retrospective cohort study included incident stroke patients seen in a cerebrovascular clinic who completed PROMIS GH between 10/12/15 and 6/6/18. Differential item functioning (DIF) evaluated measurement invariance of patient versus proxy responses. DIF impact was assessed by comparing the initial score to the DIF-adjusted score. Subgroup analyses evaluated DIF within strata of stroke severity, measured by modified Rankin Scale (≤ 1, 2, 3+), and time since stroke (≤ 30, 31-90, > 90 days).
Results:
Of 1351 stroke patients (age 60.5 ± 14.9, 45.1% female), proxy help completing PROMIS GH was required by 406 patients (30.1%). Proxies indicated significantly worse response to all items. No items for GMH or GPH were identified as having meaningful DIF. In subgroup analyses, no DIF was found by severity or 31-90 days post-stroke. In patients within 30 and > 90 days of stroke, DIF was detected for 2 items. Accounting for DIF had negligible effects on scores.
Conclusions:
Our findings revealed the overestimation of symptoms by proxies is a real difference and not the result of measurement non-invariance. PROMIS GH items do not perform differently or have spuriously inflated severity estimates when administered to proxies instead of patients.
Related Concept Videos
Global Climate Change
pH Scale
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...

