Related Experiment Video
Updated: Jan 29, 2026

Point-of-Care Ultrasound: A Review of Ultrasound Parameters for Predicting Difficult Airways
Published on: April 7, 2023
Novel dynamic corneal response parameters in a practice use: a critical review
Magdalena Jędzierowska1, Robert Koprowski2
1Department of Biomedical Computer Systems, Faculty of Computer Science and Materials Science, Institute of Computer Science, University of Silesia, ul. Będzińska 39, 41-200, Sosnowiec, Poland. magdalena.jedzierowska@us.edu.pl.
Background:
Non-contact tonometers based on the method using air puff and Scheimpflug's fast camera are one of the latest devices allowing the measurement of intraocular pressure and additional biomechanical parameters of the cornea. Biomechanical features significantly affect changes in intraocular pressure values, as well as their changes, may indicate the possibility of corneal ectasia. This work presents the latest and already known biomechanical parameters available in the new offered software. The authors focused on their practical application and the diagnostic credibility indicated in the literature.
Discussion:
An overview of available literature indicates the importance of new dynamic corneal parameters. The latest parameters developed on the basis of biomechanics analysis of corneal deformation process, available in non-contact tonometers using Scheimpflug's fast camera, are used in the evaluation of laser refractive surgery procedures, e.g. LASIK procedure. In addition, the assessment of changes in biomechanically corrected intraocular pressure confirms its independence from changes in the corneal biomechanics which may allow an intraocular pressure real assessment. The newly developed Corvis Biomechanical Index combined with the corneal tomography and topography assessment is an important aid in the classification of patients with keratoconus.
Conclusion:
New parameters characterising corneal deformation, including Corvis Biomechanical Index and biomechanical compensated intraocular pressure, significantly extend the diagnostic capabilities of this device and may be helpful in assessing corneal diseases of the eye. Nevertheless, further research is needed to confirm their diagnostic pertinence.
More Related Videos
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
04:00Author Spotlight: Establishing a Practical and Cost-Effective Protocol for Corneal Sensitivity Testing in Clinical Settings
Published on: August 2, 2024
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Critical Thinking I
Critical Thinking II