Posterior laryngofissure using a surgical contact diode laser: an experimental feasibility study
Arteiro Queiroz Menezes1,2,3, Paulo Francisco Guerreiro Cardoso4, Christopher Kengo Nagao1
1Division of Thoracic Surgery, Thoracic Surgery Research Laboratory (LIM-61), Heart Institute (InCor) do Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Rua Dr. Eneas de Carvalho Aguiar 44, Bloco I, 7° andar, São Paulo, SP, 05403-000, Brazil.
Abstract:
To evaluate the feasibility of a 980-nm contact diode laser (CDL) as a method for creating a posterior laryngofissure in live pigs. Twenty-eight Landrace pigs (15-20 kg) were anesthetized, intubated, ventilated, and submitted to a cervical tracheostomy. An anterior and posterior midline longitudinal laryngofissure incision was created according to randomization-control (n = 4), posterior laryngofissure with a scalpel blade; electrocautery (n = 12), posterior laryngofissure by electrocautery (10, 15, 20, 25 W powers); CDL (n = 12), posterior laryngofissure by the CDL (10, 15, 20, 25 W peak powers in pulsed mode). Larynx and proximal trachea were excised, prepared for histopathology, and digital morphometric analysis. Measurements in and within each group were analyzed (Kruskal-Wallis and Dunn test) with a level of significance of p < 0.05. Incision width was not different between the groups, as well as in the powers used in CDL (p = 0.161) and electrocautery group (p = 0.319). The depth of the incisions was smaller in the Laser group compared to control (p = 0.007), and in the electrocautery compared to control (p = 0.026). Incision area was smaller in CDL compared with the control (p = 0.027), and not different between laser and electrocautery groups (p = 0.199). The lateral thermal damage produced by electrocautery was the largest, with a significant difference between laser and electrocautery (p = 0.018), and between electrocautery and control (p = 0.004), whereas the comparison between laser and control showed no significant differences (p = 0.588). The posterior laryngofissure incision using a 980-nm CDL is feasible resulting in smaller incisional area and less lateral thermal damage.
Related Concept Videos
Zener Diodes
The Ideal Diode
Diode: Forward bias
The behavior of a diode in forward bias...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Modeling of Diode Forward Characteristics