Binaural advantages in using a cochlear implant for adults with profound unilateral hearing loss
Artur Lorens1, Marika Kruszyńska1, Anita Obrycka1
1a Institute of Physiology and Pathology of Hearing , Warsaw , Poland.
Background:
Recent studies of cochlear implants (CIs) in profound unilateral hearing loss (UHL) patients have demonstrated a restoration of some binaural hearing.
Aims/Objectives:
The objective was to evaluate three possible advantages of binaural hearing in CIs adult users with UHL including single-side deafness (SSD) and asymmetric hearing loss (AHL) subgroups.
Material And Methods:
A prospective study was conducted that included 70 sequentially implanted patients. Subgroups of these subjects included 64 with a postlingual onset of a profound hearing loss on the implanted side and 6 with a prelingual onset of that loss. Three binaural effects - redundancy, head shadow, and squelch - were evaluated.
Results:
Significant differences between the 'CI on' and 'CI off' conditions were found for all three binaural effects for the study group as a whole and for the postlingual subgroup. However, results for the subjects in the prelingual subgroup did not demonstrate any of the binaural advantages.
Conclusion And Significance:
Patients with a postlingual onset of a profound hearing loss in one ear and normal hearing or only a moderate loss in the other ear are able to make the effective use of a CI in the profound-loss ear in conjunction with acoustic stimulation of the other ear.
Related Concept Videos
Hearing
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...