Does the Tube Voltage Affect the Characterization of Coronary Plaques on 100- and 120-kVp Computed Tomography Scans
Takanori Masuda, Takeshi Nakaura1, Yoshinori Funama2
1Diagnostic Radiology, Graduate School of Medical Sciences, and.
Objective:
The aim of this study was to compare the diagnostic performance of 100- and 120-kVp coronary computed tomography (CT) angiography (CCTA) scans for the identification of coronary plaque components.
Methods:
We included 116 patients with coronary plaques who underwent CCTA and integrated backscatter intravascular ultrasound studies. On 100-kVp scans, we observed 24 fibrous and 24 fatty/fibrofatty plaques; on 120-kVp scans, we noted 27 fibrous and 41 fatty/fibrofatty plaques. We compared the fibrous and the fatty/fibrofatty plaques, the CT number of the coronary lumen, and the radiation dose on scans obtained at 100 and 120 kVp. We also compared the area under the receiver operating characteristic (ROC) curve of the coronary plaques on 100- and 120-kVp scans with their ROC curves on integrated backscatter intravascular ultrasound images.
Results:
The mean CT numbers of fatty and fatty/fibrofatty plaques were 5.71 ± 36.5 and 76.6 ± 33.7 Hounsfield units (HU), respectively, on 100-kVp scans; on 120-kVp scans, they were 13.9 ± 29.4 and 54.5 ± 22.3 HU, respectively. The CT number of the coronary lumen was 323.1 ± 81.2 HU, and the radiation dose was 563.7 ± 81.2 mGy-cm on 100-kVp scans; these values were 279.3 ± 61.8 HU and 819.1 ± 115.1 mGy-cm on 120-kVp scans. The results of ROC curve analysis identified 30.5 HU as the optimal diagnostic cutoff value for 100-kVp scans (area under the curve = 0.93, 95% confidence interval = 0.87-0.99, sensitivity = 95.8%, specificity = 78.9%); for 120-kVp plaque images, the optimal cutoff was 37.4 HU (area under the curve = 0.87, 95% confidence interval = 0.79-0.96, sensitivity = 82.1%, specificity = 85.7%).
Conclusions:
For the discrimination of coronary plaque components, the diagnostic performance of 100- and 120-kVp CCTA scans is comparable.
More Related Videos
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Role of Affect in Interpersonal Attraction
The Influence of Affect on Cognition
The Influence of Cognition on Affect
Voltage