Related Experiment Video
Updated: Jan 29, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Angiography-Based Machine Learning for Predicting Fractional Flow Reserve in Intermediate Coronary Artery Lesions
Hyungjoo Cho1, June-Goo Lee2, Soo-Jin Kang1
11 Department of Cardiology University of Ulsan College of Medicine Asan Medical Center Seoul Korea.
Abstract:
Background An angiography-based supervised machine learning ( ML ) algorithm was developed to classify lesions as having fractional flow reserve ≤0.80 versus >0.80. Methods and Results With a 4:1 ratio, 1501 patients with 1501 intermediate lesions were randomized into training versus test sets. Between the ostium and 10 mm distal to the target lesion, a series of angiographic lumen diameter measurements along the centerline was plotted. The 24 computed angiographic features based on the diameter plot and 4 clinical features (age, sex, body surface area, and involve segment) were used for ML by XGBoost. The model was independently trained and tested by 2000 bootstrap iterations. External validation with 79 patients was conducted. Including all 28 features, the ML model with 5-fold cross-validation in the 1204 training samples predicted fractional flow reserve ≤0.80 with overall diagnostic accuracy of 78±4% (averaged area under the curve: 0.84±0.03). The 12 high-ranking features selected by scatter search were involved segment; body surface area; distal lumen diameter; minimal lumen diameter; length of a lumen diameter <2.0 mm, <1.5 mm, and <1.25 mm; mean lumen diameter within the worst segment; sex; diameter stenosis; distal 5-mm reference lumen diameter; and length of diameter stenosis >70%. Using those 12 features, the ML predicted fractional flow reserve ≤0.80 in the test set with sensitivity of 84%, specificity of 80%, and overall accuracy of 82% (area under the curve: 0.87). The averaged diagnostic accuracy in bootstrap replicates was 81±1% (averaged area under the curve: 0.87±0.01). External validation showed accuracy of 85% (area under the curve: 0.87). Conclusions Angiography-based ML showed good diagnostic performance in identifying ischemia-producing lesions and reduced the need for pressure wires.
Related Concept Videos
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology
Coronary Artery Disease V: Interprofessional Care
Coronary Artery Disease III: Clinical Manifestations
Coronary Artery Disease IV: Preventive Measures
The Intermediate Value Theorem

