Feasibility study of a double resonant (1H/23Na) abdominal RF setup at 3T
Matthias Malzacher1, Jorge Chacon-Caldera1, Nadia Paschke1
1Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Abstract:
Sodium magnetic resonance imaging (MRI) of the human abdomen is of increasing clinical interest for e.g. kidney, intervertebral disks, prostate and tumor monitoring examinations in the abdomen. To overcome the low MR sensitivity of sodium, optimal radio frequency (RF) structures should be used. A common approach is to combine a volumetric transmit coil for homogeneous excitation with an array of sensitive receive coils adapted to the human shape. Additionally, proton imaging is required to match the physiological sodium images to the morphological proton images. In this work, we demonstrated the feasibility of a double resonant proton/sodium RF setup for abdominal MRI at 3T, providing a high sodium sensitivity. After extensive simulations, a 16-channel sodium receive array was built and used in combination with a volumetric sodium transmit coil. Additionally, a local proton coil was included in the setup for anatomical localizations. The setup was investigated using electromagnetic field simulations, phantom measurements and final in-vivo measurements of a healthy volunteer. A 3 to 6-fold sensitivity improvement of the sodium receive array compared to the volumetric sodium coil was achieved using the phantom simulations and measurements. Safety assessments of the local proton transmit/receive coil were performed using specific absorption rate simulations. Finally, the feasibility of such a setup was proven by in-vivo measurements.
More Related Videos
05:37Rapid in-silico Battery Electrolyte Electrochemical Reaction Generation using 3T-VASP Multi-Scale Energy Minimization
Published on: August 22, 2025
06:41Optimizing the Setup and Conditions for Ex Vivo Electroretinogram to Study Retina Function in Small and Large Eyes
Published on: June 27, 2022
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Resonance
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Imaging Studies IV: Magnetic Resonance Imaging
Fixing Double-strand Breaks
Fixing Double-strand Breaks