Evaluation of BioFoam for Anastomotic Bleeding in Cardiovascular Surgery
1Department of Cardiac Surgery, Ospedale San Raffaele, Milan, Italy.
Background:
Hemostatic agents are increasingly used as an adjunct to standard methods of controlling anastomotic bleeding in surgical procedures. The purpose of this study was to investigate the safety and effectiveness of BioFoam Surgical Matrix used as an adjunct for anastomotic hemostasis following cardiovascular surgery.
Methods:
A prospective, multicenter, single arm study was conducted with 75 subjects treated with BioFoam following a total of 105 elective cardiovascular surgical procedures. Time to hemostasis was recorded following a single application of BioFoam in 74 subjects. Safety evaluations included intraoperative administration of a blood product, requirement for alternative means to achieve hemostasis, and the incidence of reoperation for bleeding.
Results:
Hemostasis within 3 minutes was achieved in 62 (84%) of the 74 subjects and within 10 minutes in 69 (93%) of these subjects. BioFoam was well tolerated. Twelve (16%) of the 75 enrolled subjects each experienced one adverse event, and 13 serious adverse events were reported in 10 (13.3%) of the subjects. None of the adverse events was considered by the Investigators to be related to BioFoam. Blood products were administered to 14 (18.6%) of the 75 subjects, banked autologous blood was given to 5 (6.6%) subjects, and 57 (75.7%) subjects required only a cell saver. Four (5.3%) of the 75 subjects required reoperation for bleeding within 24 hours of surgery. There were no observations of bleeding in any subject at discharge and no reoperation for bleeding following discharge. The mean operation time was 218.2 (±72.2) minutes.
Conclusions:
This study demonstrates the effectiveness of BioFoam Surgical Matrix when used as an adjunct for anastomotic hemostasis following a broad range of cardiovascular surgical procedures. The safety outcomes were within the normal limits for the types of procedures performed.
More Related Videos
Related Concept Videos
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...
Regulation of the Cardiovascular System
The regulation of the cardiovascular system involves the autonomic nervous system (ANS), baroreceptors, and chemoreceptors, ensuring that heart rate and blood pressure are appropriately modulated in response to varying physiological demands.
The ANS comprises two main divisions: the sympathetic and parasympathetic nervous systems. The sympathetic nervous system enhances...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Psychoneuroimmunology: Cardiovascular Disease
A key area of focus in PNI is the relationship between stress and coronary...