Related Experiment Video
Updated: Jan 29, 2026

Murine Drinking Models in the Development of Pharmacotherapies for Alcoholism: Drinking in the Dark and Two-bottle Choice
Published on: January 7, 2019
Study on Speciation of As, Cr, and Sb in Bottled Flavored Drinking Water Samples Using Advanced Analytical Techniques
Wiktor Lorenc1, Barbara Markiewicz2, Dariusz Kruszka3
1Department of Trace Element Analysis by Spectroscopy Method, Faculty of Chemistry, Adam Mickiewicz University in Poznan, 89b Umultowska Street, 61-614 Poznan, Poland. wlorenc@amu.edu.pl.
Abstract:
The main aim of the research was to develop a complementary analytical approach consisting of bespoke speciation analysis and non-targeted speciation analysis of As, Sb, and Cr in flavored bottled drinking water samples using HPLC/ICP-DRC-MS and ESI-MS/MS. The scope of two previously developed analytical procedures, (1) multielemental speciation procedure for AsIII, AsV, CrVI, SbIII, and SbV analysis and (2) arsenic speciation procedure for AsB, AsIII, DMA, MMA, and AsV quantification, was extended to the analysis of a new sample type in terms of bespoke speciation analysis. As for the non-targeted speciation, analysis size exclusion chromatography was used with ICP-MS and a complementary technique, ESI-MS/MS, was used for the organic species of As, Sb, and Cr screening. Full validation of procedures 1 and 2 was conducted. Procedure 1 and 2 were characterized with precision values in the range from 2.5% to 5.5% and from 3.6% to 7.2%, respectively. Obtained recoveries ranged from 97% to 106% and from 99% to 106% for procedures 1 and 2, respectively. Expanded uncertainties calculated for procedures 1 and 2 ranged from 6.1% to 9.4% and from 7.4% to 9.9%, respectively. The applicability of the proposed procedures was tested on bottled drinking water samples. Results for the real samples in procedure 1 were in the range from 0.286 ± 0.027 [μg L-1] to 0.414 ± 0.039 [μg L-1] for AsIII, from 0.900 ± 0.083 [μg L-1] to 3.26 ± 0.30 [μg L-1] for AsV, and from 0.201 ± 0.012 [μg L-1] to 0.524 ± 0.032 [μg L-1] for SbV. CrVI and SbIII were not detected in any sample. As for procedure 2, results were in the range from 0.0541 ± 0.0053 [μg L-1] to 0.554 ± 0.054 [μg L-1] for AsB. Results for AsIII and AsV obtained with procedure 2 were in good accordance with results obtained with procedure 1. DMA and MMA were not detected in any sample.
More Related Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
08:45Modeling Alcohol Consumption in Rodents Using Two-Bottle Choice Home Cage Drinking and Microstructural Analysis
Published on: November 8, 2024
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Genetics of Speciation
Speciation Rates
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Development of Analytical Methods