Related Experiment Video
Updated: Jan 29, 2026

A Novel Method for Involving Women of Color at High Risk for Preterm Birth in Research Priority Setting
Published on: January 12, 2018
Expired Tidal Volume Variation in Extremely Low Birth Weight and Very Low Birth Weight Infants on Volume-Targeted
Samuel Wong1, Honglang Wang2, Robert Tepper3
1Section of Neonatology, Indiana University, Indianapolis, Indiana.
Insights
Volume-targeted ventilation (VTV) ensured consistent small tidal volume delivery for extremely low birth weight (ELBW) and very low birth weight (VLBW) infants. This method proved effective regardless of infant size or set volume.
Area of Science:
- Neonatal medicine
- Pediatric respiratory care
- Critical care for newborns
Background:
- Extremely low birth weight (ELBW) and very low birth weight (VLBW) infants often require mechanical ventilation.
- Precise control of tidal volumes is crucial to minimize lung injury in vulnerable neonates.
- Existing ventilation methods may struggle to deliver consistent tidal volumes in this population.
Purpose of the Study:
- To evaluate the efficacy of volume-targeted ventilation (VTV) in delivering precise tidal volumes to ELBW and VLBW infants.
- To assess the consistency of tidal volume delivery irrespective of infant characteristics or ventilator settings.
Main Methods:
- A prospective study was conducted involving ELBW and VLBW infants.
- Volume-targeted ventilation (VTV) mode was utilized for respiratory support.
- Tidal volume delivery was monitored and analyzed.
Main Results:
- VTV demonstrated consistent tidal volume delivery in both ELBW and VLBW infant groups.
- Delivery consistency was maintained independently of infant's gestational age.
- Tidal volume delivery remained consistent regardless of birth weight or the targeted volume setting.
Conclusions:
- Volume-targeted ventilation (VTV) is an effective mode for precise respiratory support in ELBW and VLBW infants.
- VTV offers reliable tidal volume delivery, potentially reducing ventilator-induced lung injury.
- This ventilation strategy provides consistent respiratory care for the most vulnerable neonates.
Abstract:
In a prospective study we describe the delivery of small tidal volumes to extremely low birth weight (ELBW) and very low birth weight (VLBW) infants using a volume-targeted ventilation mode (VTV). Tidal volume delivery was consistent for both ELBW and VLBW infants independent of gestational age, birth weight, and the target volume.
Related Concept Videos
Birth Control Methods
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Atomic Weight
Mass and Weight
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...