Refractive correction with multifocal intraocular lenses after radial keratotomy
Bárbara Martín-Escuer1, José F Alfonso2,3, Luis Fernández-Vega-Cueto1
1Fernández-Vega Ophthalmological Institute, Oviedo, Spain.
Purpose:
To assess visual and refractive results of multifocal intraocular lens (IOLs) implantation for refractive correction after radial keratotomy (RK).
Methods:
In a retrospective non-comparative interventional case series, we analyzed the outcomes of multifocal IOL implantation performed in the context of cataract or refractive lens exchange surgery following RK. A total of 17 eyes from nine patients were included in the study. IOL power calculation was done using the Double-K formula. Refractive error was used to assess predictability, and distance-corrected visual acuity (DCVA) and uncorrected distance visual acuity (UDVA) values were used to assess the surgical procedure's efficacy and safety. Distance-corrected near visual acuity (DCNVA) was also determined.
Results:
Phacoemulsification and multifocal IOL implantation was successful in all cases, with neither complications nor adverse events. At 6 months postoperatively, monocular UDVA, DCVA, and DCNVA were 0.51 ± 0.39, 0.20 ± 0.30, and 0.11 ± 0.11, respectively (logMAR scale). More specifically, 35.29% of the eyes had DCVA ≥20/20 and 52.94% showed DCVA ≥20/25. Regarding pre- vs. post-operative changes, 52.94% had lost one line of DCVA, 23.53% showed no changes, 11.76% had gained one line of DCVA, 5.88% had gained two lines, and 5.88% had gained three or more lines. The efficacy and safety indexes were 0.56 and 0.98, respectively. As for near vision surgical outcomes, 29.41% of the eyes had DCNVA ≥20/20 and 64.71% had DCNVA ≥20/25. As for surgical accuracy, 29% of the eyes were within ±0.50 D of the target refraction, whereas 65% were within ±1.00 D.
Conclusions:
Multifocal IOL implantation following radial keratotomy (RK) does not result in good distance visual performance, at least after 6 months of follow-up. Thus, this surgical approach has to be considered with only limited expectations.
Related Concept Videos
Distance Corrections
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Power Factor Correction
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
NMR Spectrometers: Resolution and Error Correction