Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Enhancing Rheumatoid Arthritis Research Through HR-pQCT Imaging Analysis
Published on: October 6, 2023
Development and Validation of an 18 F-Fluorodeoxyglucose-Positron Emission Tomography With Computed Tomography-Based
Sang Jin Lee1, Ju Hye Jeong2, Chang-Hee Lee2
1Kyungpook National University Hospital and Kyungpook National University, Daegu, Republic of Korea.
Objective:
Clinical joint count assessment is important for detecting synovitis but its reliability is a subject of controversy. This study was undertaken to assess the correlation of positron emission tomography (PET)-derived parameters in 68 joints with disease activity and to compare the reliability of joint counts between PET with computed tomography (CT) and clinical assessment in patients with rheumatoid arthritis (RA).
Methods:
We enrolled 91 patients with active RA (69 in a development group and 22 in a validation group) who underwent concurrent 18 F-fluorodeoxyglucose (18 F-FDG)-PET-CT and clinical disease activity evaluation. PET-derived parameters were compared with disease activity assessed using clinical joint count parameters. A Disease Activity Score (DAS) using counts of PET-positive joints was developed, and then validation studies were performed in an independent group.
Results:
The number of PET-positive joints (of 28 and 68 joints) was significantly correlated with the swollen joint count (SJC) and tender joint count (TJC) and the DAS in 28 joints using the erythrocyte sedimentation rate (DAS28-ESR). Intraobserver and interobserver reliability of PET for the affected joint counts were excellent. Interobserver reliability between nuclear medicine physicians and rheumatologists was good for the SJC and TJC in both 28 joints and 68 joints. After multivariate analyses, including ESR and patient's global assessment of disease activity (PtGA) in addition to PET-derived parameters, the PET/DAS was derived as (0.063 × number of PET-positive joints in 28 joints) + (0.011 × ESR) + (0.030 × PtGA). A significant correlation between the PET/DAS and the DAS28-ESR was confirmed in the validation group (P < 0.001).
Conclusion:
PET-CT could serve as a sensitive and reliable method in the evaluation of disease activity in RA patients, and may be applicable as a research tool, particularly in clinical trials.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...