Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method
Published on: July 6, 2012
Use and reliability of multiplex bead-based assays (Luminex) at Containment Level 4
Stuart D Dowall1, Victoria A Graham1, Tom Fletcher2
1Public Health England, Porton Down, Salisbury, Wiltshire SP4 0JG, UK.
Abstract:
In the UK, research on hazard group 4 (HG4) pathogens requires specialised Containment Level 4 (CL4) facilities. These differ from Biosafety Level 4 (BSL4) conditions in that work is conducted in class III microbiological safety cabinets for primary containment instead of using positive pressure suits. This presents unique challenges associated with the physical restrictions of working in a limited space, and prohibits the use of many techniques and specialist equipment. In consequence, detailed studies on the biology of HG4 pathogens and in particular their immunological relationships with the host are understudied in the UK; for example, the majority of immunological assays with which the immune system is interrogated require specialist equipment that is unsuitable for CL4. Multiplexing to simultaneously measure multiple analytes is increasingly being used in immunological studies. This assay is attractive for CL4 work because it reduces the time spent in the laboratory whilst maximising the use of valuable sample volume. The Luminex microsphere approach allows for the determination of many cytokines and chemokines, however, the detection system uses fixed aligned lasers and integrated computer systems which are unsuitable for use at CL4. Therefore, we have developed an approach in which the Luminex assay is conducted within the CL4 laboratory and a formalin-fixation stage is introduced to allow for analysis to be undertaken outside of containment. Quality control preparations allow the assay characteristics to be monitored and analysis of assay performance to be evaluated. Our data demonstrate that Luminex is an applicable tool for use at CL4 and that assays can be run reliably to generate reproducible standardised data across different plates and individual experiments.
Related Concept Videos
Reliability and Validity
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
Distribution Reliability and Automation
Leveling Effect
High-Level and Low-Level Awareness
Levels of Organization
Molecules Are Composed of Atoms, and Biomolecules Are Assembled from Molecules:
The most basic levels include atoms, molecules, and biomolecules. Atoms, the smallest unit of ordinary matter, are composed of a nucleus and electrons. Molecules...