Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: Expanding the Scope of Multiplex Immunoassays for Lyme Borreliosis Diagnostics and Pathogen Research
Published on: July 14, 2023
Dialysed caramel as an effective fluorophore for the simultaneous detection of three nitrophenols
1State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China.
Abstract:
Low-cost and nontoxic fluorescent reagents are important for on-site analysis performed by non-professionals. In this work, a cheap and widely available food additive, caramel was used as an effective fluorescence reagent for the sensitive detection of 2,4,6-trinitrophenol (TNP), 2,4-dinitrophenol (DNP) and 4-nitrophenol (4-NP). Through a simple dialysis, fluorescent components of a commercial caramel were harvested with a yield as high as 60%. The structural characterization demonstrated that the fluorescent components were dehydrated oligomers of carbohydrates. Their fluorescence can be quenched by these nitrophenols. The quenching mechanism was speculated as inner filter effect. At pH 8, a linear range of 0.2-22 μM and a detection limit of 90 nM could be achieved for TNP. Based on the difference of their quenching efficiency at different pHs, TNP, DNP and 4-NP can be simultaneously determined by solving the linear equations obtained at pH 3, 5 and 8. Successful detection of these nitrophenols in the water and soil samples was performed with relative standard deviations of 1.1-5.9% and recoveries of 95-108% of spiked standards.
More Related Videos
06:31Author Spotlight: Innovative Laser Techniques for Hoechst Staining to Analyze Side Population Cells
Published on: August 23, 2024
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Biological Effects of Radiation
Framing Effects
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Self-Awareness and Its Effects