Operating mode selection for the separation of intermediately-eluting components with countercurrent and centrifugal
Raena Morley1, Mirjana Minceva1
1Biothermodynamics, TUM School of Life Sciences Weihenstephan, Technical University of Munich, Maximus-von-Imhof-Forum 2, 85354 Freising, Germany.
Abstract:
Two operating modes that can be used for the separation of intermediately-eluting target components from complex mixtures using solid support-free liquid-liquid chromatography (LLC) include batch injections and trapping multiple dual mode (trapping MDM). Batch injections offer the advantage of simpler equipment and process design, while the trapping MDM process, although more complex, can provide improved resolution at low separation factors. In this study, a thorough comparison of batch injection and trapping MDM performance with respect to productivity is made using simulations for a wide range of separation tasks (target component/impurity separation factors; minimum purity and yield requirements). For each separation task, the maximum productivities obtained by the two operating modes were separately determined with respect to their independent parameters. The results indicate that trapping MDM can be used to extend the application of LLC down to separation factors as low as 1.1, with its use being most advantageous for separation factors of approximately 1.3. However, the simpler batch injection process remains preferable for separation factors around or greater than 1.5.
More Related Videos
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
Related Concept Videos
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
High-Performance Liquid Chromatography: Elution Process
Centrifugation
The Intermediate Value Theorem
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Disassembly of Intermediate Filaments
Keratin proteins, found at the cell periphery near cell junctions, undergo a cycle of assembly and disassembly. In Type...