Diagnostic Value of Advanced Imaging Modalities for the Detection and Differentiation of Prosthetic
Jin Young Kim1, Young Joo Suh2, Kyunghwa Han2
1Department of Radiology, Dongsan Medical Center, Keimyung University College of Medicine, Daegu, Korea.
Objectives:
This meta-analysis investigated the diagnostic values of transthoracic echocardiography (TTE), 2-dimensional (2D) and 3-dimensional (3D) transesophageal echocardiography (TEE), and multidetector-row computed tomography (MDCT) in patients with suspected mechanical prosthetic valve obstruction (PVO) for detecting subprosthetic mass and differentiating its causes.
Background:
Diagnostic values of advanced imaging modalities, such as MDCT and TEE, for the detection and differentiation of PVO have not been investigated.
Methods:
PubMed and EMBASE were systematically searched for studies that evaluated PVO using imaging modalities. The modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate study quality. Pooled sensitivity of each modality for PVO detection and pooled diagnostic accuracy of TEE and MDCT for differentiating the causes of PVO were analyzed. Study heterogeneity was also assessed.
Results:
Seventeen studies (229 patients) that used at least 1 index tool among TTE, TEE, or MDCT were included. For detecting a subprosthetic mass that caused PVO, 3D TEE and MDCT showed a higher sensitivity of 81% (95% confidence interval [CI]: 40% to 95%) and 88% (95% CI: 81% to 93%), respectively, compared with TTE (20%; 95% CI: 7% to 47%) and 2D TEE (68%; 95% CI: 46% to 84%). Pooled sensitivity and specificity for diagnosing thrombus as a cause of PVO was 75% (95% CI: 54% to 88%) and 75% (95% CI: 40% to 93%), respectively, for TEE and 45% (95% CI: 16% to 77%) and 90% (95% CI: 77% to 96%), respectively, for MDCT. Pooled sensitivity for diagnosing pannus as a cause of PVO was 62% (95% CI: 46% to 76%) for TEE and 85% (95% CI: 70% to 93%) for MDCT.
Conclusions:
This meta-analysis suggested that MDCT and 3D TEE have higher sensitivity than do TTE and 2D TEE, and can be reliable imaging modalities for detecting a subprosthetic mass that causes PVO. Moreover, MDCT can more accurately differentiate the cause of PVO than does TEE.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Sensory Modalities
General senses refer to the broad category of sensory information detected by receptors in the body and can be further grouped into somatic and visceral senses. Somatic sensations include touch, pressure, temperature, and pain and are essential for navigating our environment and...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...