Objective:
To obtain reference values of aortic valve area (AVA) in a large population and to infer the risk of overestimating aortic stenosis (AS) when focusing on flow-corrected indices of severity.
Methods:
We prospectively measured indices of AS in all consecutive echocardiograms performed in a large referral cardiac imaging laboratory for 1 year. We specifically analysed the distribution of AVA, indexed AVA and velocity ratio (Vratio) in patients with and without AS, the latter defined as the coexistence of valvular outflow obstruction (Vmax ≥2.5 m/s) and morphological findings of valve degeneration.
Results:
16 156 echocardiograms were analysed, 14 669 of which did not show valvular obstruction (peak jet velocity <2.5 m/s). In the latter group, AVA was 2.6±0.7 cm2 in 8190 studies with normal valves and 2.3±0.7 cm2 in 6479 studies with aortic sclerosis (AScl). There was a relatively wide overlap between values of AVA, indexed AVA and velocity ratio between studies of patients with AScl and AS. Values of AVA ≤1.0 cm2 were found in 0.5% of studies with normal valves and 1.8% of studies with AScl. These proportions were 3.1% and 9.3% for AVA ≤1.5 cm2, respectively. Vratio ≤0.25 were found in 0.1% of patients without obstruction. Risk factors for a small AVA in patients without obstruction were AScl, female sex, small body surface area, low ejection fraction and mitral regurgitation.
Conclusions:
Normal values of continuity-equation derived AVA are smaller than previously considered. AVA values below cutoffs of moderate or severe AS can be found in patients without the disease. Flow-corrected indices may overestimate AS in patients with low gradients, particularly in the presence of well-identified risk factors.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
05:47Isolation of Mouse Interstitial Valve Cells to Study the Calcification of the Aortic Valve In Vitro
Published on: May 10, 2021
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Relative Risk
Mitral Stenosis I: Introduction
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Mitral Stenosis III: Medical Management
Mitral Valve Prolapse I: Introduction