No difference in outcomes between femoral fixation methods with hamstring autograft in anterior cruciate ligament
Eoghan T Hurley1, Arianna L Gianakos2, Utkarsh Anil3
1Department of Orthopaedic Surgery, New York University Langone Health, NY, New York, United States of America; Department of Trauma & Orthopaedic Surgery, Royal College of Surgeons in Ireland, Dublin, Ireland.
Background:
There is mixed opinion regarding the optimal femoral fixation method for hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction. Currently, no study exists showing a superior method of femoral fixation, and thus the topic has remained controversial. The purpose of this study is to network meta-analyze the randomized control trials comparing cortical-button (CB), cross-pin (CP) and interference screws (IS) for femoral fixation with hamstring tendon autograft in ACL reconstruction.
Methods:
The literature review was conducted in accordance with the PRISMA guidelines. Randomized control trials comparing CB, CP and IS were included. Clinical outcomes were compared using a frequentist approach to network meta-analysis, with all statistical analysis performed using R, with a p-value <0.05 being considered statistically significant.
Results:
There were 11 studies included comparing; 194 patients with CB to 201 patients with CP (6 studies), 48 patients with CB to 50 patients with IS (1 study), and 172 patients with CP to 162 patients with IS (5 studies). One study compared all three groups, including 48 patients with CB, 50 patients with IS, and 52 with CP. There was a mean follow-up time of 26.4 months. No statistically significant difference was found between the fixation methods when evaluating knee stability, functional outcomes, graft failures, or revision procedures.
Conclusion:
Using a network meta-analysis, our study found that, there was no difference in failure rate, knee stability, functional outcomes or incidence of revision procedures between CB, CP or IS femoral fixation techniques of hamstring tendon autografts in ACL reconstruction.
Level Of Evidence:
Level I, network meta-analysis of Level I studies.
Related Concept Videos
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Predicting Reaction Outcomes
Directing Effect of Substituents: meta-Directing Groups
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...