Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Hsin-Ting Lin1, Yi-Lin Shiou2, Wun-Jyun Jhuang2
1Division of Cardiology, Department of Internal Medicine, Kaohsiung Medical University Hospital; Hematology and Oncology, China Medical University Hospital.
Abstract:
For studies related to cardiovascular physiology or pathophysiology, blood pressure (BP) and electrocardiography are basic observational parameters. Research focusing on cardiovascular disease models, potential cardiovascular therapeutic targets or pharmaceutical agents requires assessment of systemic arterial pressure and heart rhythm changes. In situations where radio telemetry systems are not available or affordable, the technique of femoral artery cannulation is an alternative way to obtain intra-arterial pressure waveform recordings and systemic BP measurements. This technique is economical and can be performed with standard equipment in animal facilities. However, invasive arterial pressure recording requires cannulation of small arteries, which can be a challenging surgical skill. Here, we present step-by-step protocols for femoral artery cannulation procedures. Key procedures include the calibration of the data acquisition system, tissue dissection and femoral artery cannulation, and setup of the arterial cannulation system for pressure recording. Surface electrocardiography recording procedures are also included. We also present examples of BP recordings from normotensive and hypertensive rats. This protocol allows reliable direct recordings of systemic BP with simultaneous electrocardiography.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer