Transoral flexible laryngoscope biopsy: Safety and accuracy
Nabeel Humayun Hassan1, Rahila Usman2, Muhammad Yousuf1
1Department of ENT Head & Neck Surgery, Shaheed Mohtarma Benazir Bhutto Medical College & Lyari General Hospital, Karachi, Pakistan.
Objective:
To determine the accuracy of transoral flexible laryngoscope (TFL) biopsy and also to identify the safety as office based procedure in terms of complications.
Methods:
This is a diagnostic study; the type of intervention is outpatient department based biopsy of laryngeal lesions. All patients seen in ENT outpatient department of Lyari General Hospital with suspicious lesions of Larynx were referred for Transoral Flexible Laryngoscopy Biopsy under local anesthesia. The specimens were sent for histopathology. The patients with benign pathology or carcinoma in situ were referred for direct laryngoscopy and biopsy. The sensitivity and specificity were calculated and the frequencies of complications were monitored to determine the complication rate.
Results:
During the course of study a total of 47 patients underwent TFL biopsy in office settings. Out of these patients 16 patients were referred for direct laryngoscopy biopsy. The study population included 32 men and 15 women with ages ranging from 28 to 52 years and mean of (39 ± 6) years. Among 43 patients squamous cell carcinoma was the final diagnosis in 31 patients. In the rest of 12 patients' dysplasia and benign lesion was the diagnosis in 9 and 3 patients respectively. These 12 patients underwent direct laryngoscopy biopsy and 10 of them diagnosed with invasive carcinoma rest had benign lesions. Hence the specificity was 75.6% and sensitivity was 100%. None of the patients developed any serious complication.
Conclusions:
All patients with a suspicious lesion diagnosed by TFL biopsy as being benign or carcinoma in situ should have direct laryngoscopy for verification of the findings. But the results positive for carcinoma are reliable. In addition, this is a safe procedure.
More Related Videos
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Survey Safety
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...