Detection of Bacillus anthracis in animal tissues using InBios active anthrax detect rapid test lateral flow
C B Kolton1, C K Marston1, R A Stoddard1
1Centers for Disease Control and Prevention, Atlanta, GA, USA.
None:
The Active Anthrax Detect (AAD) Rapid Test lateral flow immunoassay is a point-of-care assay that was under investigational use for detecting Bacillus anthracis capsular polypeptide (polyglutamic acid) in human blood, serum and plasma. Small sample volumes, rapid results and no refrigeration required allow for easy use in either the field or laboratory. Although the test was developed for use in suspect cases of human inhalation anthrax, its features also make it a potentially powerful tool for testing suspect animal cases. We tested animal tissue samples that were confirmed or ruled out for B. anthracis. The AAD Rapid Tests were also deployed in the field, testing animal carcasses during an anthrax outbreak in hippopotami (Hippopotamus amphibius) and Cape buffalo (Syncerus caffer) in Namibia. Evaluation of all samples showed a specificity of 82% and sensitivity of 98%. However, when the assay was used on specimens from only fresh carcasses (dead for <24 h), the specificity increased to 96%. The AAD Rapid Test is a rapid and simple screening assay, but confirmatory testing needs to be done, especially when the age of the sample (days animal has been deceased) is unknown. SIGNIFICANCE AND IMPACT OF THE STUDY: In countries where anthrax is endemic, many human outbreaks are often caused by epizootics. Earlier detection of infected animals may allow for identification of exposed people, early implementation of prevention and control methods, and ultimately lessen the number of people and animals affected. Detection of Bacillus anthracis in animal tissues using a simple, rapid and field-deployable method would allow for faster outbreak response. We evaluated a simple sample collection and processing method for use with the Active Anthrax Detect Rapid Test lateral flow immunoassay to screen dead animals for anthrax.
More Related Videos
08:01Detection of Invasive Pulmonary Aspergillosis in Haematological Malignancy Patients by using Lateral-flow Technology
Published on: March 22, 2012
13:47Opsono-Adherence Assay to Evaluate Functional Antibodies in Vaccine Development Against Bacillus anthracis and Other Encapsulated Pathogens
Published on: May 19, 2020
Related Concept Videos
Rapidly Varying Flow
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...