Related Experiment Video
Updated: Jan 29, 2026

Whole Animal Perfusion Fixation for Rodents
Published on: July 30, 2012
Dynamic Fixation Versus Static Fixation for Distal Tibiofibular Syndesmosis Injuries: A Meta-Analysis
Kaifeng Gan1, Ke Zhou1, Keqi Hu1
1Department of Orthopaedics, Ningbo Medical Center Lihuili Hospital, Ningbo, Zhejiang, China (mainland).
Abstract:
BACKGROUND Ankle sprains with distal tibiofibular syndesmosis injuries (DTSIs) require anatomic reduction and fixation to restore the normal biomechanics of the ankle joint. In the last decade, dynamic fixation (DF) for DTSIs using a suture-button device has gained popularity because of its advantages over static fixation (SF). MATERIAL AND METHODS The present meta-analysis was conducted to compare clinical outcomes between DF and SF of DTSIs. PubMed, Cochrane Central Register of Controlled Trials, and Embase were systematically searched. Three randomized controlled studies and 7 cohort studies, with a total of 420 patients, were involved in this study. DTSIs patients treated with DF were assigned to the experimental group, and patients treated with SF were assigned to the control group. Outcomes were evaluated and analyzed by using review-manager software. Mean difference (MD) or risk ratio (RR) with 95% confidence interval (95% CI) was analyzed and calculated by utilizing the random effects models. RESULTS Analysis revealed no statistically significant differences between DF and SF in American Orthopedic Foot and Ankle Society Ankle-Hindfoot score (MD, 1.90; 95% CI, -0.23-4.03; p=0.08; I²=0%), Olerud-Molander score (MD, 1.92; 95% CI, -7.96-11.81; p=0.70; I²=55%), incidence of syndesmotic malreduction (RR, 0.19; 95% CI, 0.03-1.09; p=0.06; I²=0%), and overall postoperative complication rate (RR, 0.30; 95% CI, 0.09-0.99; p=0.05, I²=75%). The rate of second procedure was significantly lower compared with DF (RR, 0.17; 95% CI, 0.07-0.43; p=0.0002, I²=54%). CONCLUSIONS The dynamic fixation and static fixation methods are equal in clinical outcomes, with dynamic fixation needing fewer second interventions for DTSIs.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
Static, Stagnation, Dynamic and Total Pressure
Static Equilibrium - I
Static Equilibrium - II
Static Friction
For example, consider a scenario where a truck is connected to a car by a rope, ready to tow it along a road. When no external force is applied by the truck, the car remains stationary and is said to be in static equilibrium. In this case, the forces acting on the car, such as gravity and the...

