McSART: an iterative model-based, motion-compensated SART algorithm for CBCT reconstruction
G Chee1, D O'Connell1, Y M Yang1
1Department of Radiation Oncology, David Geffen School of Medicine, UCLA, Los Angeles, CA, United States of America.
None:
4D cone beam computed tomography (CBCT) images of the thorax and abdomen can have reduced quality due to the limited number of projections per respiratory bin used in gated image reconstruction. In this work, we present a new algorithm to reconstruct high quality CBCT images by simultaneously reconstructing images and generating an associated respiratory motion model. This is done by updating model parameters to compensate for motion during the iterative image reconstruction process. CBCT image acquisition was simulated using the digital eXternal CArdiac Torso (XCAT) phantom, simulating breathing motion using four patient breathing traces. 4DCBCT images were reconstructed using the simultaneous algebraic reconstruction technique (SART), and compared to the proposed motion-compensated SART (McSART) algorithm. McSART used a motion model that describes tissue position as a function of diaphragm amplitude and velocity. The McSART algorithm alternately updated the motion model and image reconstruction, increasing the number of projections used for image reconstruction with every iteration. The model was able to interpolate and extrapolate deformations according to the magnitude of the surrogate signal. Without noise, the final iteration McSART images had HU errors at 31%, 34%, and 44% of their SART-reconstructed counterparts compared to ground truth XCAT images, with corresponding root-mean-square (RMS) motion model errors of 0.75 mm, 1.08 mm, and 1.17 mm respectively. With added image noise, McSART's HU error was 31% of the SART-reconstructed 4DCBCT error, with a 1.43 mm RMS motion model error. Qualitatively, blurring and streaking artifacts were reduced in all the reconstructed images compared to 3D or SART-reconstructed 4DCBCT. The output of the algorithm was a high quality reference image and a corresponding motion model, that could be used to deform the reference image to any other point in a breathing cycle.
More Related Videos
07:05Area-based Image Analysis Algorithm for Quantification of Macrophage-fibroblast Cocultures
Published on: February 15, 2022
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Dosage Compensation
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Trial and Error and Algorithm
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...