Dual-Energy Computed Tomography Pulmonary Angiography: Comparison of Vessel Enhancement between Linear Blended and
Andrew Murphy1, Jeffrey Cheng2, Jit Pratap2
1Department of Medical Imaging, British Columbia Children's Hospital, Vancouver, Canada; Department of Medical Imaging, St Paul's Hospital, Vancouver, Canada; Faculty of Health Sciences, The University of Sydney, Discipline of Medical Radiation Sciences, Cumberland Campus, Lidcombe, Australia.
Introduction:
Optimal opacification of the pulmonary vasculature is a fundamental factor of a diagnostic quality computed tomography pulmonary angiogram (CTPA). This retrospective study examined the feasibility of utilising a noise-optimised monoenergetic reconstruction of the dual-energy computed tomography pulmonary angiogram (DE-CTPA) as an additional protocol to increase vessel opacification.
Method:
The study involved a retrospective analysis of 129 patients, 69 males (average age 58 years), 60 females (average age 56 years) who underwent a DE-CTPA at a tertiary referral hospital. Linear blended 120 kilovoltage (kV) images (LB120) dual-energy (DE) data sets (50% 100 kV and 50% 140 kV) were compared to noise-optimised virtual monoenergetic image reconstruction (VMI+) at 40 kiloelectron volts (VMI+40). The attenuation of the pulmonary trunk measured in Hounsfield units (HU) between the equivalent axial slices of the LB120 data set and the VMI+40 data set underwent statistical analysis via a Wilcoxon paired-sample test.
Results:
VMI+40 (1161.500 HU) yielded a statistically significant increase in median attenuation within the pulmonary trunk compared to the LB120 (304.400 HU), with a median difference between monoenergetic reconstruction and standard dual energy of data sets of 827.5 HU (P < .001).
Conclusions:
VMI+40 of the DE-CTPA scan demonstrates a statistically significant increase in vessel attenuation in all cases and may have utility in reducing the rates of indeterminate or repeated studies.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Voltammetric Techniques: Linear-Scan (E vs Time)
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
What is Energy?


