Screw track osteolysis is a risk in cementless total knee arthroplasty (TKA) with screw fixation. Titanium wear may contribute to this tibial osteolysis, though screw angles
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Pathology
Background:
- Limited reports exist on osteolysis linked to tibial screw fixation in cementless total knee arthroplasty (TKA).
- The underlying pathophysiology of screw track osteolysis in cementless TKA remains unclear.
Purpose of the Study:
- To describe the pathology of screw track osteolysis around the tibia in cementless TKA.
- To investigate potential contributing factors to this phenomenon.
Main Methods:
- Analysis of 100 revised cementless TKAs with tibial screw fixation.
- Radiological assessment of osteolysis and screw angles.
- Histopathological and biochemical analysis of tissue and wear debris.
- Electrochemical evaluation of screw-tray interactions.
Main Results:
- Screw track osteolysis was prevalent medially, correlating with smaller screw angles.
- Osteolysis showed high titanium concentrations, but not polyethylene particles.
- Tissue analysis revealed necrosis, osteolytic cysts, and inflammatory cells.
Conclusions:
- Cementless TKA with screw fixation carries a risk of screw track osteolysis.
- Titanium wear is a potential contributor to screw track osteolysis in this TKA design.
- The role of screw angles in osteolysis requires further investigation.
More Related Videos
09:46Construction and Evaluation of a Murine Calvarial Osteolysis Model by Exposure to CoCrMo Particles in Aseptic Loosening
Published on: February 17, 2018
04:59Using a Knee Arthrometer to Evaluate Tissue-specific Contributions to Knee Flexion Contracture in the Rat
Published on: November 9, 2018
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Group Design
Continuous Renal Replacement Therapy