Asymmetric Wide-Bandgap Polymers Simultaneously Improve the Open-Circuit Voltage and Short-Circuit Current for

Shaorong Huang1, Wanying Gu2, Lie Chen1

  • 1College of Chemistry/Institute of Polymers and Energy Chemistry, Nanchang University, Nanchang, 330031, P. R. China.

Related Concept Videos

Voltage Doubler Circuit01:23

Voltage Doubler Circuit

A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
1.7K
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
551
Current Growth And Decay In RL Circuits01:30

Current Growth And Decay In RL Circuits

The current growth and decay in RL circuits can be understood by considering a series RL circuit consisting of a resistor, an inductor, a constant source of emf, and two switches. When the first switch is closed, the circuit is equivalent to a single-loop circuit consisting of a resistor and an inductor connected to a source of emf. In this case, the source of emf produces a current in the circuit. If there were no self-inductance in the circuit, the current would rise immediately to a steady...
4.6K
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
686
Second-Order Circuits01:17

Second-Order Circuits

Integrating two fundamental energy storage elements in electrical circuits results in second-order circuits, encompassing RLC circuits and circuits with dual capacitors or inductors (RC and RL circuits). Second-order circuits are identified by second-order differential equations that link input and output signals.
Input signals typically originate from voltage or current sources, with the output often representing voltage across the capacitor and/or current through the inductor. For example, in...
3.5K
First-Order Circuits01:15

First-Order Circuits

First-order electrical circuits, which comprise resistors and a single energy storage element - either a capacitor or an inductor, are fundamental to many electronic systems. These circuits are governed by a first-order differential equation that describes the relationship between input and output signals.
One common example of a first-order circuit is the RC (resistor-capacitor) circuit. These circuits are used in relaxation oscillators such as neon lamp oscillator circuits. When voltage is...
3.8K