Related Experiment Video
Updated: Jan 29, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Evaluation of regional myocardial perfusion in methamphetamine abusers using real-time myocardial contrast
Xiao-Zhi Zheng1, Yun-Yan Shi2, Ke-Qi Chen3
1Yancheng Institute of Clinical Medicine (The First People's Hospital of Yancheng), Xuzhou Medical University. zxzycyy1232@163.com.
Aims:
To evaluate the feasibility of assessing regional myocardial perfusion using real-time myocardial contrast echocardiography (MCE) at rest for detecting coronary microcirculation abnormalities in methamphetamine abusers.Material and methods: Twenty-two male methamphetamine abusers (11 without chest pain, 11 with chest pain), free of ascertained coronary artery disease, were enrolled in this study. A control group of 22 age-matched male healthy participants was studied for comparison. Standard 2D, flow and tissue Doppler echo with measurements of cardiac morphologic and functional indicators,MCE with measurements of regional myocardial perfusion were performed, respectively.
Results:
Compared to healthy participants, methamphetamine abusers had higher blood pressure, greater left ventricular mass index and more impaired diastolic function, with preserved cardiac sizes and systolic function. Methamphetamine abusers with chest pain had a faster heart rate than those without chest pain and healthy participants. MCE in methamphetamine abusers, especially with chest pain, had significant longer contrast agent arrival times, less functional capillary blood volumes, slower microvascular flow velocities and less myocardial perfusion than healthy participants (p<0.05). Moreover, along with the increases of dosage and duration of use (from group A to group C, group A: 1-2 g/day, <2 years; group B: 2-3 g/day, 2-5 years; group C: >3 g/day, >5 years) the reductions in the myocardial perfusion indices were more significant (p<0.01). The cutoff value with 5.1 dB2/s of the myocardial perfusion at the left ventricular apex had a sensitivity of 87.5%, specificity of 75.2% and accuracy of 81.9% for differentiating methamphetamine abusers from normal subjects.
Conclusions:
Real-time MCE can effectively detect coronary microcirculation abnormalities in methamphetamine abusers at rest and myocardial perfusion is significantly reduced in methamphetamine abusers. This finding may be involved in the occurrence and development of cardiac damage.
More Related Videos
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Drug Abuse and Addiction: Pharmacological Phenomena
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
IR Frequency Region: Fingerprint Region
The Eukaryotic Promoter Region
Region of Convergence