The effect of reduced contrast sensitivity on colour vision testing
Lior Lipsky1,2, Hanya M Qureshi3, Ronit Friling2,4
1Ophthalmology Department, Tel Aviv Medical Center, Tel Aviv, Israel.
Objective:
To assess the effect of reduced contrast sensitivity on three commonly used colour vision tests in order to establish key discrepancies that may be relevant for clinical practice.
Methods:
A prospective non-interventional clinical study of colour vision testing using three commonly used devices: Ishihara and Hardy-Rand-Rittler (H-R-R) pseudoisocochromatic plate tests, and Farnsworth D-15 arrangement test performed under progressively reduced contrast sensitivity conditions achieved with a neutral density filter bar.
Results:
The Pelli-Robson contrast sensitivity (PRCS) at which 5% of the population should first experience a 10% reduction in colour vision testing from baseline was calculated for each of the three colour vision devices: Farnsworth D-15 test: 1.81 log contrast sensitivity (CS), H-R-R test: 1.69 log CS, and Ishihara test: 1.34 log CS. Single factor repeated measures analyses, conducted separately at each contrast sensitivity level, revealed no difference between the colour vision testing devices at PRCS ≥1.80 log CS (P ≥ 0.367). However, in all PRCS ≤1.65 log CS, the differences were statistically significant (all P ≤ 0.004), demonstrating a significantly lower percentage of errors in the Ishihara test compared with both the Farnsworth D-15 (P < 0.023) and H-R-R (P < 0.035) tests.
Conclusions:
At high contrast sensitivities, all colour vision tests function almost equally; however, at decreased levels of contrast sensitivity, H-R-R and Farnsworth D-15 are more greatly affected.
More Related Videos
09:29A Standardized Obstacle Course for Assessment of Visual Function in Ultra Low Vision and Artificial Vision
Published on: February 11, 2014
04:00Author Spotlight: Establishing a Practical and Cost-Effective Protocol for Corneal Sensitivity Testing in Clinical Settings
Published on: August 2, 2024
Related Concept Videos
Vision
Color Vision
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Depth Perception and Spatial Vision
Methods of reducing fever
Pharmacological Methods of Reducing Fever: