Related Experiment Video
Updated: Jan 28, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Significant regional variation in use of implantable cardioverter-defibrillators in Denmark
Susanne Bendesgaard Pedersen1, Dóra Körmendiné Farkas2, Søren Pihlkjær Hjortshøj3
1Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus N, Denmark.
Aims:
Implantable cardioverter-defibrillator (ICD) treatment prevents sudden cardiac death in high-risk patients. This study examined geographical variation in ICD implantation rates in Denmark and potential causes of variation.
Methods And Results:
We obtained numbers of ICD implantations in the 5 Danish regions and 98 municipalities during 2007-13 from the Danish Pacemaker and ICD Registry. Standardized implantation rates (SIRs) were computed as ICD implantations per 1 000 000 person-years, and age- and gender-standardized to the Danish population. We examined associations of the municipal SIR with mean age and Charlson Comorbidity Index score of ICD recipients, percentage of implantations with primary prophylactic indication, and distance from patient residency to ICD implanting centre. Based on 7192 ICD implantations, the nationwide SIR was 186 [95% confidence interval (CI) 182-190], ranging from 170 (95% CI 158-183) in the North Denmark Region to 206 (95% CI 195-218) in the Region of Zealand. Municipalities with higher patient comorbidity scores, higher percentages of implantations with primary prophylactic indication, and shorter distances to ICD implanting centres, had higher SIRs [differences between SIRs of municipalities in highest and lowest quartiles 22 (95% CI 10-34), 45 (95% CI 33-58), and 35 (95% CI 24-47), respectively]. Regional differences in SIRs decreased over time and had become insignificant during 2011-13.
Conclusion:
Implantable cardioverter-defibrillator implantation rates in Denmark varied significantly between regions but variation decreased during 2007-13. Geographical variation was associated with differences in patient comorbidity score, variation in use of primary prophylactic ICD treatment, and distance to ICD implanting centre.
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...