Pulse Pressure Variations and Plethysmographic Variability Index Measured at Ear Are Able to Predict Fluid
Lionel Bapteste1, Romain Carrillon1, Stéphanie Javelier2
1Department of Anesthesiology, Groupement Hospitalier Est.
Background:
Pulse pressure variation (PPV) and plethysmographic variability index (PVI), dynamic indicators of preload dependence based on heart-lung interactions, are used to predict fluid responsiveness in mechanically ventilated patients in the supine position. The sitting position for neurosurgery, by changing intrathoracic blood volume, could affect the capacity of PPV and PVI to predict fluid responsiveness. The aim of the study was to assess the ability of PPV and PVI to predict fluid responsiveness during general anesthesia in the sitting position.
Methods:
In total, 31 patients were included after settling in the sitting position but before surgery began. PPV, PVI with a finger sensor (PVI finger), and PVI with an ear sensor (PVI ear) were recorded before and after a fluid challenge of hydroxylethylstarch 250 mL over 10 minute. Esophageal Doppler was used to record stroke volume. Patients were defined as fluid responders if stroke volume increased by more than 10% after the fluid challenge.
Results:
In total, 13 (42%) patients were fluid responders. PPV and PVI ear were higher in responders than in nonresponders before the fluid challenge (12±5 vs. 7±3; P=0.0005 and 14±5 vs. 8±3; P=0.001, respectively). Areas under the receiver-operating curves to predict fluid responsiveness were 0.87 for PPV (P<0.0001), 0.87 for PVI ear (P<0.0001), and 0.64 for PVI finger (P=0.17). PPV ≥8% or PVI ear ≥11% predicted fluid responsiveness with sensitivities of 83% for both, and specificities of 83% and 91%, respectively. However PVI ear data were not available in 26% of patients.
Conclusions:
PPV can be used to predict fluid responsiveness in the sitting position for neurosurgery.
Related Concept Videos
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Pressure of Fluids
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...