Related Experiment Video
Updated: Jan 28, 2026

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
Studying the effect of bioswales on nutrient pollution in urban combined sewer systems
Nandan H Shetty1, Ranran Hu2, Brian J Mailloux3
1Department of Civil Engineering and Engineering Mechanics, Columbia University, 500 West 120(th) Street, 610 Mudd, New York, NY 10027, USA.
Abstract:
The objective of this study was to evaluate the impact of bioswales on nutrient pollution in an urban combined sewershed. This evaluation was based on two criteria: the ability of bioswales to (1) remove nutrient pollution from stormwater runoff directly and (2) decrease sewer overflow volumes, which indirectly reduces total sewershed nutrient pollution during a storm event. Bioswales' direct nutrient removal was determined by analyzing nitrogen and phosphorus levels in water samples at seven bioswales located in the Bronx, New York City (NYC) over 42 storm events, while a bioswale's indirect nutrient removal through combined sewer overflow reduction was estimated by quantifying water retention at one of the bioswales. The study results indicated that: 1) the bioswale retained about 40% of stormwater conveyed to it from a drainage area 231 times its size, 2) bioswales leach nutrients into the subsurface, and 3) nitrogen leaching from bioswales varied seasonally, while phosphorus leaching decreased steadily over the study period. Although the studied bioswales leached a median 1.3 kg nitrogen per year into the subsurface, they provided an aggregate decrease in watershed nutrient pollution, from 7.7 to 6 kg nitrogen per year, due to their reduction of combined sewer overflow via stormwater retention.
Related Concept Videos
Absorption of Nutrients
Enterocytes, which are specialized polar epithelial cells, line the mucosa of the small intestinal walls. These cells...
Second Order systems II
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Thermodynamic Systems
Consider an example of tea boiling in a kettle. The...
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:

