Related Experiment Video
Updated: Jan 28, 2026

Quantification of Violacein in Chromobacterium violaceum and Its Inhibition by Bioactive Compounds
Published on: August 8, 2025
Development of a MD-LC-MS/MS Method to Analyze 3 Bioactive Compounds in Huoxuezhitong Rubber Patch and Application to
Yahua Cui1, Chang Yang1, Jun Liang1
1School of Chinese Materia Medica, Beijing University of Chinese Medicine, Fangshan District 102488, Beijing, China.
Abstract:
Huoxuezhitong rubber patch, a well-known traditional Chinese medicine (TCM) prescription, is utilized to treat pain and inflammation. In this study, a microdialysis-ultra-high-performance liquid chromatography-tandem mass spectrometry (MD-LC-MS/MS) method was designed for the simultaneous determination of active constituents in the rubber patch, such as paeonol (Pae), eugenol (Eug), and piperine (Pip). A microdialysis probe was implanted in the subcutaneous tissue of a rat, which is intended to detect the subcutaneous concentrations of target components. Saline containing 30% ethanol acted as perfusion fluid. Analytes in the microdialysate were completely separated over an ACQITY UPLC RBEH C18 column (2.1mm×100mm, 1.7μm). The mobile phase was composed of 0.01% ammonia aqueous and acetonitrile-0.01% ammonia with gradient elution. The single-run analysis time was 10.0 minutes. The linear regression displayed good linear relationships in the ranges of 0.25-100 ng/mL for paeonol and eugenol and 0.001-5 ng/mL for piperine. The interday and intraday precision of the quality control samples exhibited relative standard deviations (RSD) <13.56%. The accuracy values ranged from -14.92% to 14.00%. The present method was successfully applied in pharmacokinetics studies following dermal administration of Huoxuezhitong rubber patch in rats. Pip's Tmax (488.00±150.73) min was greater than that of Pae (186.67±48.44) min and Eug (240.00±138.56) min, and the rank order of t1/2 was Pae > Pip > Eug. The rank order of AUC0-720 and Cmax was both Eug > Pae > Pip. MRT0-∞ of Pip was higher than that of Pae and Eug. Eugenol showed a faster elimination and a shorter half-life. Paeonol showed a stronger drug reservoir function after removing the drug source.
Related Concept Videos
Piaget's Stage 3 of Cognitive Development
Conservation and Constancy of Quantity
A significant cognitive milestone in the...
Measurement of Bioavailability: Pharmacokinetic Methods
Development of Analytical Methods
Long-patch Base Excision Repair
Statistical Methods for Analyzing Epidemiological Data
Molecules and Compounds

