Radicioni Maurizio1, Victoria Elisa Rinaldi2, Pier Giorgio Camerini1
1Neonatal Intensive Care Unit, Santa Maria Della Misericordia Hospital of Perugia, Perugia, Italy.
Objectives:
To test the reproducibility and report the reference ranges of the right diaphragmatic excursion's peak velocities recorded by pulsed wave tissue Doppler imaging in healthy term neonates.
Methods:
We formerly assessed intraobserver and interobserver variability of the method for the right hemidiaphragm in a small group of neonates, including ventilated neonates. We did not attempt to test the approach for the left hemidiaphragm because of the recognized high failure rate of visualization. Next, we recorded the peak velocities of both hemidiaphragms throughout inspiration and expiration in 229 healthy term neonates near birth to establish weight-dependent reference ranges for the measurements.
Results:
The study population included 116 male and 113 female neonates. The reproducibility of the technique was excellent even in neonates supported by ventilation. We always recorded the right diaphragmatic peak velocities in the normative study group, whereas the left ones were only recorded in 110 of 229 (48%) and 148 of 229 (65%) neonates from the anterior and lateral views, respectively. The modality of delivery and sex showed no influence on diaphragmatic kinetics. The mean inspiratory peak velocities ± SD were 1.4 ± 0.2 cm/s for the right hemidiaphragm and 1.5 ± 0.3 cm/s for the left hemidiaphragm. The mean expiratory peak velocities were 1.3 ± 0.2 cm/s for the right hemidiaphragm and 1.4 ± 0.3 cm/s for the left hemidiaphragm.
Conclusions:
Measurement of right diaphragmatic kinetics as assessed by pulsed wave tissue Doppler imaging was found to be a reliable technique. Its clinical applicability for the prompt diagnosis and effective management of neonatal respiratory failure deserves further investigation.
Related Concept Videos
Velocity and Acceleration of a Wave
The velocity of the particles can be obtained by taking the partial derivative of the position equation with respect to time....
Equations of Wave Motion
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
The Wave Nature of Light
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Velocity and Position by Graphical Method