VAMPIRE® fundus image analysis algorithms: Validation and diagnostic relevance in hypertensive cats
Related Experiment Video
Updated: Jan 28, 2026

Area-based Image Analysis Algorithm for Quantification of Macrophage-fibroblast Cocultures
Published on: February 15, 2022
Alessandro Cirla1,2, Michele Drigo3, Lucia Ballerini4
1Department of Ophthalmology, San Marco Veterinary Clinic and Laboratory, Veggiano, Italy.
Insights
The VAMPIRE® software effectively diagnoses feline hypertension by analyzing retinal vasculature. This tool objectively measures changes in feline retinal arteries and veins, aiding in early detection of systemic hypertension.
Area of Science:
- Veterinary Ophthalmology
- Comparative Medicine
- Medical Imaging Analysis
Background:
- Systemic hypertension in cats can lead to significant ocular complications.
- Objective diagnostic tools are needed to assess retinal vascular changes in feline hypertension.
- The VAMPIRE® (Vascular Assay and Measurement Platform for Images of the Retina) software, developed for human use, has potential applications in veterinary medicine.
Purpose of the Study:
- To validate the VAMPIRE® software for analyzing feline retinal vasculature.
- To assess the clinical utility of VAMPIRE® in identifying hypertensive cats.
- To investigate the correlation between retinal vascular parameters and systemic hypertension in felines.
Main Methods:
- 105 healthy cats (normal group) and 43 hypertensive cats (clinical group) were enrolled.
- Digital retinal images were analyzed using VAMPIRE® software, measuring 11 vascular points (veins, arteries, bifurcations).
- Repeatability and reproducibility were assessed by two independent operators; data analyzed using Mann-Whitney and Tukey box plots (P < 0.05).
Main Results:
- 210 retinal images yielded 2310 measurements; mean vein diameter was 9.1 pixels, mean artery diameter was 6.1 pixels.
- Arteriolar bifurcation angles averaged 73.6°, 76.9°, and 85.4° for first, second, and third bifurcations, respectively.
- Hypertensive cats showed significantly reduced arteriolar diameter (3.3 pixels) and branch angles (55°, 47.8°, 59.9°) with increased vein diameter (24.15 pixels) compared to healthy cats.
Conclusions:
- The VAMPIRE® algorithm is a viable tool for objective diagnosis of retinal vascular changes in cats.
- The software demonstrated clinical utility in differentiating hypertensive from healthy feline subjects.
- VAMPIRE® can serve as an additional diagnostic aid for feline systemic hypertension, extending human medical imaging techniques to veterinary applications.
Objectives:
To validate a retinal imaging software named VAMPIRE® (Vascular Assay and Measurement Platform for Images of the Retina) in feline patients and test the clinical utility in hypertensive cats.
Animals Studied:
One hundred and five healthy cats were enrolled. They represented the normal dataset used in the validation (group 1). Forty-three hypertensive cats with no noticeable retinal abnormalities were enrolled for the clinical validity of the software (group 2).
Procedures:
Eleven points (4 veins, 4 arteries, and 3 arterial bifurcations) were measured for each digital image. Repeatability and reproducibility of measurements were assessed using two independent operators. Data were statistically analyzed by the Mann-Whiney and Tukey box plot. Significance was considered when P < 0.05.
Results:
Two hundred and ten retinal images were analyzed for a total of 2310 measurements. Total mean was 9.1 and 6.1 pixels for veins and arteries, respectively. First, second, and third arteriolar bifurcations angles were 73.6°, 76.9°, and 85.4°, respectively. A comparison between groups 1 and 2 showed a statistically significant reduction in arteriolar diameter (mean 3.3 pixels) and branch angle (55°, 47.8° and 59.9°) associated with increasing vein diameter (mean 24.15 pixels).
Conclusions:
Current image analysis techniques used in human medicine were investigated in terms of extending their use to veterinary medicine. The VAMPIRE® algorithm proved useful for an objective diagnosis of retinal vasculature changes secondary to systemic hypertension in cats, and could be an additional diagnostic test for feline systemic hypertension.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Reliability and Validity
Trial and Error and Algorithm
Hypertension I: Introduction
Hypertension II: Pathophysiology
Data Validation
Key parameters for method validation include: