Microfabricated liquid junction hybrid capillary electrophoresis-mass spectrometry interface for fully automated

Jana Krenkova1, Karel Kleparnik1, Jaroslav Luksch1

  • 1Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic.

Electrophoresis
|February 23, 2019
PubMed

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
1.1K
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.3K
Rise of Liquid in a Capillary Tube01:18

Rise of Liquid in a Capillary Tube

When very thin cylindrical tubes, called capillaries, are dipped in a liquid, the liquid rises or falls in the tube compared to the surrounding liquid. This phenomenon is called capillary action. Capillary action occurs due to the combination of two opposing forces: the cohesive forces of the liquid, which cause it to stick to itself and form a rounded shape, and the adhesive forces between the liquid and the walls of the container, which cause the liquid to be attracted to the container walls.
3.2K
Mass Spectrometry: Overview01:19

Mass Spectrometry: Overview

Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
8.6K
Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.5K
Mass Spectrometry of Amines01:15

Mass Spectrometry of Amines

In mass spectroscopy, amines undergo fragmentation to give parent ions with odd molecule weights. This observed mass spectrum follows the nitrogen rule; a molecule with an odd number of nitrogen atoms produces a molecular ion with an odd molecular weight. Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit strong molecular ion peaks, but acyclic...
5.4K