Related Experiment Video
Updated: Jan 28, 2026

A Model of Free Tissue Transfer: The Rat Epigastric Free Flap
Published on: January 15, 2017
Numerical simulations of different configured venous anastomosis in microvascular flap transfer
Julian Wittenborn1, Martin Büsen2, Sam Liao2
1Department of Cranio-Maxillofacial Surgery, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Background:
Free flap surgery is a well-established method for covering large defects in the head and neck region. Most cases of flap failure are caused by venous thrombosis. Thus, there is a lot of discussion about the ideal design of venous anastomosis and its impact on the hemodynamics in the vessels. This study concentrates on the simulation of flow patterns of different designs of venous anastomoses.
Methods:
First, fluid flow rates were measured using transit-time flow measurement in the veins of 20 patients who received free flaps between 2016 and 2017. Five different designs of porcine anastomoses were scanned using micro-computed tomography, to create three-dimensional models. In the second step, numerical simulations of the blood flow were performed to gain insights into the vessel flow patterns.
Results:
The simulations revealed recirculation areas in the 60° and 90° end-to-side anastomoses, especially in combination with low fluid flow rates. In addition, there were large areas of recirculation in the 1:3 end-to-end anastomoses.
Conclusion:
The type of venous anastomosis should be decided individually. End-to-side anastomosis can be recommended in cases with high caliber differences or in those with high venous outflow. End-to-end anastomoses should be preferred in conditions with low venous outflow.
Related Concept Videos
Numerical Calculations
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...

