Use of 5-0 Fast Absorbing Gut versus 6-0 Fast Absorbing Gut during cutaneous wound closure on the head and neck: A
Aunna Pourang1, Milene K Crispin2, Ashley K Clark1
1Department of Dermatology, University of California, Davis, Sacramento, California.
Background:
Absorbable suture material (Fast Absorbing Gut [FG], Ethicon, Somerville NJ) is often used for patient convenience; however, the optimal diameter of FG sutures is debatable.
Objective:
To determine whether the use of 6-0 FG during repair of linear cutaneous surgery wounds on the head and neck improves scar cosmesis compared with the use of 5-0 FG.
Methods:
This was a prospective, randomized, split-scar intervention in patients undergoing repair of linear cutaneous wounds on the head and neck. The scar was assessed 3 months after surgery via the Physician Observer Scar Assessment Scale (POSAS), a validated instrument.
Results:
The difference in the sum of the POSAS component scores for 6-0 FG (12.03) compared with that for 5-0 FG (13.11) was not statistically significant (P = .26). Observer overall opinion was similar for both interventions, at 2.49 for 6-0 FG vs 2.64 for 5-0 FG (P = .54). The difference in the number of complications in the 5-0 FG group (15) vs the 6-0 FG group (10) was not statistically significant (P = .40).
Limitations:
Single-center study with wounds limited to the head and neck in white individuals, with a predominance of men.
Conclusion:
For linear repair of cutaneous wounds, 6-0 FG was not statistically different for cosmetic outcomes, scar width, and complications compared with 5-0 FG.
Related Concept Videos
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Fast Fourier Transform
The computational efficiency of the FFT becomes...
Fast Decoupled and DC Powerflow
Gene Evolution - Fast or Slow?
In contrast, regions which code...
Gene Evolution - Fast or Slow?