Related Experiment Video
Updated: Jan 28, 2026

Trans-vivo Delayed Type Hypersensitivity Assay for Antigen Specific Regulation
Published on: May 2, 2013
Clinical interpretation of prostate-specific antigen values: Type of applied cut-off value exceeds methods bias as
Lieke Jj Klinkenberg1, Eef Gwm Lentjes2, Arjen-Kars Boer1
11 Clinical Laboratory, Catharina Hospital, Eindhoven, the Netherlands.
Background:
Prostate-specific antigen is the biochemical gold standard for the (early) detection and monitoring of prostate cancer. Interpretation of prostate-specific antigen is both dependent on the method and cut-off. The aim of this study was to examine the effect of method-specific differences and cut-off values in a national external quality assessment scheme (EQAS).
Methods:
The Dutch EQAS for prostate-specific antigen comprised an annual distribution of 12 control materials. The results of two distributions were combined with the corresponding cut-off value. Differences between methods were quantified by simple linear regression based on the all laboratory trimmed mean. To assess the clinical consequence of method-specific differences and cut-off values, a clinical data-set of 1040 patients with an initial prostate-specific antigen measurement and concomitant conclusive prostate biopsy was retrospectively collected. Sensitivity and specificity for prostate cancer were calculated for all EQAS participants individually.
Results:
In the Netherlands, seven different prostate-specific antigen methods are used. Interestingly, 67% of these laboratories apply age-specific cut-off values. Methods showed a maximal relative difference of 26%, which were not reflected in the cut-off values. The largest differences were caused by the type of cut-off, for example in the Roche group the cut-off value differed maximal 217%. Clinically, a fixed prostate-specific antigen cut-off has a higher sensitivity than an age-specific cut-off (mean 89% range 86-93% versus 79% range 63-95%, respectively).
Conclusions:
This study shows that the differences in cut-off values exceed the method-specific differences. These results emphasize the need for (inter)national harmonization/standardization programmes including cut-off values to allow for laboratory-independent clinical decision-making.
Related Concept Videos
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Confirmation Biases
Hindsight Biases
Clinically Relevant Drug Product Specifications: Methods of Establishment
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Biodiversity and Human Values

