Related Experiment Video
Updated: Jan 28, 2026

Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
[The prognostic value of the hip screw position in intertrochanteric fractures]
Ákos Csonka1, Tamás Ecseri1, Dávid Dózsai1
1Traumatológiai Klinika, Szegedi Tudományegyetem, Általános Orvostudományi Kar Szeged, Semmelweis u. 6., 6725.
Introduction:
In our study, we analyzed one of the Hungarian population's most frequent injuries, the hip fracture, focusing mainly on the lateral femoral neck and the pertrochanteric fractures. According to the classification of the Swiss Association for Ostheosynthesis (AO), we focused on 31-A1 and 31-A2 fractures, the incidence of which increases by ageing.
Method:
Between 2010 and 2016, we analyzed the data of 1179 patients. All of the fractures were stabilized with intramedullary nails. 992 patients received Stryker Gamma3®, whereas 187 patients' fractures were solved with Synthes PFNA® nail. In all cases, closed reduction method was used with fluoroscopy on an extension table. The surgeries were done in general or epidural anesthesia and performed by traumatology residents or specialists using standard lateral exploration. Data were collected using GEPACS software and statistical analysis was done with MS Excel.
Results:
Cut-out occurred in 33 cases (2,79%): out of that 21 (1.78%) were left sided and 12 were (1,01%) right sided. 29 (87.87%) patients were treated with Gamma3 nail, and in 4 (12,12%) cases PFNA nail was used. The average TAD-index was 18 mm.
Conclusion:
According to recommendations of the TAD-index value, when using dynamic hip screw, it should be 20 mm or lower. The average index value was 18 mm which was equal in the complicated and non-complicated groups. Our study shows that the cut-out is independent from the TAD-index value, thus this recommendation cannot be applied for intramedullary nails. Orv Hetil. 2019; 160(9): 338-342.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Position-effect Variegation
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Position and Displacement