Related Experiment Video
Updated: Jan 28, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Antioxidants as a novel dental resin-composite component: Effect on elution and degree of conversion
Yang Yang1, Franz-Xaver Reichl2, Nicoleta Ilie3
1Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Germany; Key Laboratory of Oral Medicine, Guangzhou Institute of Oral Disease, Stomatology Hospital of Guangzhou Medical University, Guangzhou 510140, China; Walther Straub Institute of Pharmacology and Toxicology, Faculty of Medicine, LMU Munich, Germany.
Objective:
Ascorbic acid (Asc) and N-acetylcysteine (NAC) were reported to reduce genotoxicity induced by dental (co)monomers and their epoxy metabolites. The aim of the present study was to investigate Asc or NAC as novel components in light-curable methacrylate based dental composites regarding their effects on degree of conversion (DC) and elution of composite components. Additionally, the release of Asc or NAC was determined.
Methods:
Asc or NAC (1, 0.1, 0.01 or 0 wt%) was experimentally incorporated into the composites Venus®, Grandio® and FiltekTM Supreme XTE and polymerized according to the instruction of manufacturers. The samples were elussted in methanol and water. For each composite-antioxidant mixture and elution medium four samples (n = 4) were prepared. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS), high-performance liquid chromatography/ultraviolett/diode array detection (HPLC/UV/DAD) and high-performance liquid chromatography/fluorescence detection (HPLC/FLD). DC of composite-antioxidant mixtures was measured in real-time with Fourier transform infrared spectroscopy (FTIR).
Results:
The highest concentrations of eluted Asc were 313.98 μM (Venus®-1 wt% Asc; 1 day; methanol) and 245.34 μM (FiltekTM Supreme XTE-1 wt% Asc; 5 min; water). The highest concentrations of eluted NAC were 42.99 μM (1 day; Filtek™ Supreme XTE-1 wt% NAC; 1 day; methanol) and 108.11 μM (Filtek™ Supreme XTE-1 wt% NAC; 7 day; water). Triethylene glycol dimethacrylate (TEGDMA) elution was significantly increased in Venus®-1 wt% Asc and Grandio®-1 wt% Asc (1 day and 7 day methanol/water), compared to control. No significant difference was found for TEGDMA elution in Filtek™ Supreme XTE-1 wt% Asc/NAC. DC was significantly decreased compared to control (= composite without antioxidant) in Grandio® and Filtek™ Supreme XTE after 1, 0.1 and 0.01 wt% Asc incorporation and in Venus® after 1 and 0.1 wt% Asc incorporation. For composite-NAC mixtures, only DC of Grandio®-1 wt% NAC was significantly reduced.
Significance:
Incorporation of NAC (1 wt%), as a novel composite component, into Filtek™ Supreme XTE, had no effect on DC and composite component elution, and supplies sufficient amount of antioxidant which may reduce toxicity. Therefore, it represents a beneficial mixture.
More Related Videos
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
10:30A Generalized Method for Determining Free Soluble Phenolic Acid Composition and Antioxidant Capacity of Cereals and Legumes
Published on: June 10, 2022
Related Concept Videos
Gene Conversion
Gene Conversion
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...