Urinary Bladder Distention Evoked Visceromotor Responses as a Model for Bladder Pain in Mice
Published on: April 27, 2014
Is submucosal bladder pressure monitoring feasible?
Anisha S Basu1,2, Steve Majerus2,3,4, Elizabeth Ferry5
11 Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
Abstract:
There has been recent interest in placing pressure-sensing elements beneath the bladder mucosa to facilitate chronic bladder pressure monitoring. Wired submucosal sensors with the wires passed through detrusor have been demonstrated in vivo, with limited chronic retention, potentially due to the cable tethering the detrusor. Published studies of submucosal implants have shown that high correlation coefficients between submucosal and lumen pressures can be obtained in caprine, feline, and canine models. We have developed a wireless pressure monitor and surgical technique for wireless submucosal implantation and present our initial chronic implantation study here. Pressure monitors were implanted (n = 6) in female calf models (n = 5). Five devices were implanted cystoscopically with a 25-French rigid cystoscope. One device was implanted suprapubically to test device retention with an intact mucosa. Wireless recordings during anesthetized cystometry simultaneous with catheter-based reference vesical pressure measurements during filling and manual bladder compressions were recorded. Individual analysis of normalised data during bladder compressions (n = 12) indicated high correlation (r = 0.85-0.94) between submucosal and reference vesical pressure. The healing response was robust over 4 weeks; however, mucosal erosion occurred 2-4 weeks after implantation, leading to device migration into the bladder lumen and expulsion during urination. Wireless pressure monitors may be successfully placed in a suburothelial position. Submucosal pressures are correlated with vesical pressure, but may differ due to biomechanical forces pressing on an implanted sensor. Fully wireless devices implanted beneath the mucosa have risk of erosion through the mucosa, potentially caused by disruption of blood flow to the urothelium, or an as-yet unstudied mechanism of submucosal regrowth. Further investigation into device miniaturisation, anchoring methods, and understanding of submucosal pressure biomechanics may enable chronic submucosal pressure monitoring. However, the risk of erosion with submucosal implantation highlights the need for investigation of devices designed for chronic intravesical pressure monitoring.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...
Constant Pressure Calorimetry
Vapor Pressure
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Anatomy of the Genitourinary System II: Bladder and Urethra