Related Experiment Video
Updated: Jan 28, 2026

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Role of Multidetector Computed Tomography (CT) Virtual Hysteroscopy in the Evaluation of Abnormal Uterine Bleeding in
Hend S Saleh1, Nadia M Madkour1, Ahmed Mahmoud Abdou1
1Obstetrics & Gynecology Departments, Faculty of Medicine, Zagazig University, Zagazig 44519, Egypt.
Background:
Abnormal uterine bleeding (AUB) may be acute or chronic and is defined as bleeding from the uterine corpus that is abnormal in regularity, volume, frequency, or duration and occurs in the absence of pregnancy. It is a widespread complaint in the primary care units. The prevalence of abnormal bleeding is up to 30% among women of reproductive age.
Objective:
To assess the role of CT virtual hysteroscopy in the evaluation of the uterine cavity in cases with abnormal uterine bleeding in reproductive age.
Methods:
Cross sectional study was performed at Obstetrics and Gynecology Department and Radiology Department, Zagazig University hospitals, Egypt, on 124 women with abnormal uterine bleeding in reproductive age, and their uterine cavity was evaluated by both row multidetector computed tomography (MDCT) scanner and Office hysteroscopy.
Results:
Mean age of studied group was 28.54 ± 5.99 years, and virtual hysteroscopy showed sensitivity 91.1% and specificity 85.3% in detection of abnormalities within uterine cavity. It showed sensitivity 91.1% and specificity 85.3% in cases of endometrial polyps. It yielded 88.5 % sensitivity and 100 % specificity in cases with submucous fibroids, while it yielded only 57.9 % sensitivity and 82.9% specificity in cases of thick endometrium.
Conclusion:
Virtual CT hysteroscopy is a good negative test in cases of abnormal uterine bleeding but has some limitations that decrease its sensitivity.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
Reproductive Cloning
Somatic Cell Nuclear Transfer
In SCNT, an egg cell is taken from an animal and its nucleus is removed, creating an enucleated egg. Then a somatic...
Abnormal Proliferation
Uterine Tubes

